Технические характеристики регулирующих картриджей автоматических балансировочных клапанов FlowCon A
|
20 мм · 3/4” · композитный картридж · тип Y
|
|||||||
|
Номинальное давление, ΔР:
20-130 кПаD (15-130 кПаD)* · 2.9-18.9 фунт/кв. дюймd (2.2-18.9 фунт/кв. дюймd)* |
|||||||
|
Номер модели
|
ABV1.Y.Y
|
ABV1.Y.R
|
ABV1.Y.U
|
ABV1.Y.B
|
ABV1.Y.G
|
||
|
л/сек
|
л/час
|
галл/мин
|
Серый*
|
Красный
|
Синий
|
Черный
|
Зеленый
|
|
0.0081
|
29.2
|
0.128
|
1
|
|
|
|
|
|
0.0133
|
47.9
|
0.211
|
2
|
|
|
|
|
|
0.0175
|
63.0
|
0.277
|
3
|
|
|
|
|
|
0.0222
|
79.9
|
0.352
|
4
|
|
|
|
|
|
0.0311
|
112
|
0.493
|
5
|
|
|
|
|
|
0.0353
|
127
|
0.560
|
6
|
|
|
|
|
|
0.0383
|
138
|
0.607
|
7
|
|
|
|
|
|
0.0431
|
155
|
0.683
|
8
|
|
|
|
|
|
0.0450
|
162
|
0.713
|
|
|
|
3
|
|
|
0.0757
|
207
|
0.911
|
|
4
|
|
|
|
|
0.0619
|
223
|
0.981
|
|
|
4
|
|
|
|
0.0669
|
241
|
1.06
|
|
|
|
4
|
|
|
0.0922
|
332
|
1.46
|
|
5
|
|
|
|
|
0.0978
|
352
|
1.55
|
|
|
|
|
1
|
|
0.105
|
378
|
1.66
|
|
6
|
|
|
|
|
0.114
|
409
|
1.80
|
|
7
|
|
|
|
|
0.115
|
415
|
1.83
|
|
|
5
|
|
|
|
0.118
|
426
|
1.88
|
|
|
|
|
2
|
|
0.119
|
430
|
1.89
|
|
|
|
|
|
|
0.136
|
489
|
2.15
|
|
8
|
|
|
3
|
|
0.137
|
492
|
2.17
|
|
|
6
|
|
|
|
0.138
|
498
|
2.19
|
|
|
|
|
4
|
|
0.146
|
524
|
2.31
|
|
|
7
|
|
|
|
0.146
|
526
|
2.32
|
|
|
8
|
|
|
|
0.155
|
557
|
2.45
|
|
|
|
5
|
|
|
0.176
|
635
|
2.80
|
|
|
|
6
|
|
|
0.180
|
647
|
2.85
|
|
|
|
7
|
|
|
0.193
|
695
|
3.06
|
|
|
|
8
|
|
|
0.231
|
830
|
3.66
|
|
|
|
|
5
|
|
0.237
|
854
|
3.76
|
|
|
|
|
6
|
|
0.253
|
909
|
4.00
|
|
|
|
|
7
|
|
0.273
|
984
|
4.33
|
|
|
|
|
8
|
|
Точность: Наибольшее значение: ±10% регулируемого расхода или 20 л/час (0.0056 л/сек или 0.088 галл/мин) |
|
20 мм · 3/4” · композитный картридж · тип G
|
|||||||
|
Номинальное давление, ΔР:
40-400 кПаD (30-400 кПаD)* · 5.8-58 фунт/кв. дюймd (4.4-58 фунт/кв. дюймd)* |
|||||||
|
Номер модели
|
ABV1.G.Y
|
ABV1.G.R
|
ABV1.G.U
|
ABV1.G.B
|
ABV1.G.G
|
||
|
л/сек
|
л/час
|
галл/мин
|
Серый*
|
Красный
|
Синий
|
Черный
|
Зеленый
|
|
0.0117
|
42.1
|
0.185
|
1
|
|
|
|
|
|
0.0189
|
68.0
|
0.300
|
2
|
|
|
|
|
|
0.0247
|
88.9
|
0.392
|
3
|
|
|
|
|
|
0.0325
|
117
|
0.515
|
4
|
|
|
|
|
|
0.0472
|
170
|
0.748
|
5
|
|
|
|
|
|
0.0528
|
190
|
0.837
|
6
|
|
|
|
|
|
0.0564
|
203
|
0.894
|
|
|
|
|
|
|
0.0597
|
215
|
0.946
|
|
|
3
|
|
|
|
0.0639
|
230
|
1.01
|
7
|
|
|
3
|
|
|
0.0694
|
250
|
1.10
|
8
|
|
|
|
|
|
0.0781
|
281
|
1.24
|
|
4
|
|
|
|
|
0.0908
|
327
|
1.44
|
|
|
4
|
|
|
|
0.0958
|
345
|
1.52
|
|
|
|
4
|
|
|
0.137
|
493
|
2.17
|
|
5
|
|
|
|
|
0.147
|
529
|
2.33
|
|
|
|
|
1
|
|
0.161
|
581
|
2.56
|
|
6
|
|
|
|
|
0.173
|
624
|
2.75
|
|
7
|
|
|
|
|
0.181
|
652
|
2.87
|
|
|
5
|
|
|
|
0.181
|
653
|
2.88
|
|
8
|
|
|
|
|
0.186
|
670
|
2.95
|
|
|
|
|
2
|
|
0.210
|
755
|
3.32
|
|
|
|
|
3
|
|
0.216
|
779
|
3.43
|
|
|
6
|
|
|
|
0.218
|
785
|
3.46
|
|
|
7
|
|
|
|
0.220
|
792
|
3.49
|
|
|
8
|
|
|
|
0.237
|
853
|
3.75
|
|
|
|
5
|
|
|
0.241
|
869
|
3.83
|
|
|
|
|
4
|
|
0.266
|
957
|
4.21
|
|
|
|
6
|
|
|
0.269
|
968
|
4.26
|
|
|
|
7
|
|
|
0.277
|
998
|
4.39
|
|
|
|
8
|
|
|
0.365
|
1320
|
5.79
|
|
|
|
|
5
|
|
0.369
|
1330
|
5.85
|
|
|
|
|
6
|
|
0.392
|
1410
|
6.21
|
|
|
|
|
7
|
|
0.408
|
1470
|
6.46
|
|
|
|
|
8
|
|
Точность: Наибольшее значение: ±10% регулируемого расхода или 20 л/час (0.0056 л/сек или 0.088 галл/мин) |
|
20 мм · 3/4” · E-JUST · Белая защелка
|
||||
|
Номинальное давление, ΔР: 17-210 кПаD · 2.5-30 фунт/кв. дюйм D
|
||||
|
Номер модели
|
E-JUST1.Y.B
|
E-JUST1.Y.G
|
||
|
л/сек
|
л/час
|
галл/мин
|
Черный
|
Зеленый
|
|
0.0278
|
100
|
0.440
|
1.0
|
|
|
0.0299
|
108
|
0.475
|
1.1
|
|
|
0.0321
|
116
|
0.509
|
1.2
|
|
|
0.0343
|
123
|
0.543
|
1.3
|
|
|
0.0364
|
131
|
0.578
|
1.4
|
|
|
0.0386
|
139
|
0.612
|
1.5
|
|
|
0.0408
|
147
|
0.646
|
1.6
|
|
|
0.0429
|
155
|
0.681
|
1.7
|
|
|
0.0436
|
157
|
0.691
|
|
1.0
|
|
0.0451
|
162
|
0.715
|
1.8
|
|
|
0.0468
|
168
|
0.741
|
|
1.1
|
|
0.0473
|
170
|
0.749
|
1.9
|
|
|
0.0494
|
178
|
0.784
|
2.0
|
|
|
0.0499
|
180
|
0.791
|
|
1.2
|
|
0.0516
|
186
|
0.818
|
2.1
|
|
|
0.0530
|
191
|
0.841
|
|
1.3
|
|
0.0538
|
194
|
0.852
|
2.2
|
|
|
0.0559
|
201
|
0.887
|
2.3
|
|
|
0.0562
|
202
|
0.890
|
|
1.4
|
|
0.0581
|
209
|
0.921
|
2.4
|
|
|
0.0593
|
214
|
0.940
|
|
1.5
|
|
0.0603
|
217
|
0.955
|
2.5
|
|
|
0.0624
|
225
|
0.990
|
2.6
|
1.6
|
|
0.0646
|
233
|
1.02
|
2.7
|
|
|
0.0656
|
236
|
1.04
|
|
1.7
|
|
0.0668
|
240
|
1.06
|
2.8
|
|
|
0.0687
|
247
|
1.09
|
|
1.8
|
|
0.0689
|
248
|
1.09
|
2.9
|
|
|
0.0711
|
256
|
1.13
|
3.0
|
|
|
0.0719
|
259
|
1.14
|
|
1.9
|
|
0.0733
|
264
|
1.16
|
3.1
|
|
|
0.0750
|
270
|
1.19
|
|
2.0
|
|
0.0754
|
272
|
1.20
|
3.2
|
|
|
0.0776
|
279
|
1.23
|
3.3
|
|
|
0.0781
|
281
|
1.24
|
|
2.1
|
|
0.0798
|
287
|
1.26
|
3.4
|
|
|
0.0813
|
293
|
1.29
|
|
2.2
|
|
0.0819
|
295
|
1.30
|
3.5
|
|
|
0.0841
|
303
|
1.33
|
3.6
|
|
|
0.0844
|
304
|
1.34
|
|
2.3
|
|
0.0863
|
311
|
1.37
|
3.7
|
|
|
0.0876
|
315
|
1.39
|
|
2.4
|
|
0.0884
|
318
|
1.40
|
3.8
|
|
|
0.0906
|
326
|
1.44
|
3.9
|
|
|
0.0907
|
327
|
1.44
|
|
2.5
|
|
0.0928
|
334
|
1.47
|
4.0
|
|
|
0.0938
|
338
|
1.49
|
|
2.6
|
|
0.0949
|
342
|
1.50
|
4.1
|
|
|
0.0970
|
349
|
1.54
|
|
2.7
|
|
0.0971
|
350
|
1.54
|
4.2
|
|
|
0.0993
|
357
|
1.57
|
4.3
|
|
|
0.100
|
360
|
1.59
|
|
2.8
|
|
0.101
|
365
|
1.61
|
4.4
|
|
|
0.103
|
372
|
1.64
|
|
2.9
|
|
0.104
|
373
|
1.64
|
4.5
|
|
|
0.106
|
381
|
1.68
|
4.6
|
|
|
0.106
|
383
|
1.69
|
|
3.0
|
|
0.108
|
389
|
1.71
|
4.7
|
|
|
0.110
|
394
|
1.74
|
|
3.1
|
|
0.110
|
396
|
1.75
|
4.8
|
|
|
0.112
|
404
|
1.78
|
4.9
|
|
|
0.113
|
406
|
1.79
|
|
3.2
|
|
0.114
|
412
|
1.81
|
5.0
|
|
|
0.116
|
417
|
1.84
|
|
3.3
|
|
0.119
|
428
|
1.89
|
|
3.4
|
|
0.122
|
440
|
1.94
|
|
3.5
|
|
0.125
|
451
|
1.98
|
|
3.6
|
|
0.128
|
462
|
2.03
|
|
3.7
|
|
0.132
|
473
|
2.08
|
|
3.8
|
|
0.135
|
485
|
2.13
|
|
3.9
|
|
0.138
|
496
|
2.18
|
|
4.0
|
|
0.141
|
507
|
2.23
|
|
4.1
|
|
0.144
|
519
|
2.28
|
|
4.2
|
|
0.147
|
530
|
2.33
|
|
4.3
|
|
0.150
|
541
|
2.38
|
|
4.4
|
|
0.153
|
553
|
2.43
|
|
4.5
|
|
0.157
|
564
|
2.48
|
|
4.6
|
|
0.160
|
575
|
2.53
|
|
4.7
|
|
0.163
|
586
|
2.58
|
|
4.8
|
|
0.166
|
598
|
2.63
|
|
4.9
|
|
0.169
|
609
|
2.68
|
|
5.0
|
|
Точность: Наибольшее значение: ±5% от контролируемого расхода или ±2% от максимального расхода. |
|
20 мм · 3/4” · E-JUST · Тип Y · Белая защелка
|
|||
|
Номинальное давление, ΔР: 17-200 кПаD · 2.5-29 фунт/кв. дюйм D
|
|||
|
Номер модели
|
E-JUST1.Y.R
|
||
|
л/сек
|
л/час
|
галл/мин
|
Черный
|
|
0.0767
|
276
|
1.22
|
1.0
|
|
0.0813
|
293
|
1.29
|
1.1
|
|
0.0860
|
310
|
1.36
|
1.2
|
|
0.0907
|
123
|
0.543
|
1.3
|
|
0.0953
|
131
|
0.578
|
1.4
|
|
0.100
|
139
|
0.612
|
1.5
|
|
0.105
|
147
|
0.646
|
1.6
|
|
0.109
|
155
|
0.681
|
1.7
|
|
0.114
|
157
|
0.691
|
1.8
|
|
0.118
|
162
|
0.715
|
1.9
|
|
0.123
|
168
|
0.741
|
2.0
|
|
0.128
|
170
|
0.749
|
2.1
|
|
0.132
|
178
|
0.784
|
2.2
|
|
0.136
|
180
|
0.791
|
2.3
|
|
0.141
|
186
|
0.818
|
2.4
|
|
0.145
|
191
|
0.841
|
2.5
|
|
0.150
|
194
|
0.852
|
2.6
|
|
0.154
|
201
|
0.887
|
2.7
|
|
0.158
|
202
|
0.890
|
2.8
|
|
0.162
|
209
|
0.921
|
2.9
|
|
0.166
|
214
|
0.940
|
3.0
|
|
0.170
|
217
|
0.955
|
3.1
|
|
0.174
|
225
|
0.990
|
3.2
|
|
0.178
|
233
|
1.02
|
3.3
|
|
0.182
|
236
|
1.04
|
3.4
|
|
0.0668
|
240
|
1.06
|
3.5
|
|
0.0687
|
247
|
1.09
|
3.6
|
|
0.0689
|
248
|
1.09
|
3.7
|
|
0.0711
|
256
|
1.13
|
3.8
|
|
0.0719
|
259
|
1.14
|
3.9
|
|
0.0733
|
264
|
1.16
|
4.0
|
|
0.0750
|
270
|
1.19
|
4.1
|
|
0.0754
|
272
|
1.20
|
4.2
|
|
0.0776
|
279
|
1.23
|
4.3
|
|
0.0781
|
281
|
1.24
|
4.4
|
|
0.0798
|
287
|
1.26
|
4.5
|
|
0.0813
|
293
|
1.29
|
4.6
|
|
0.0819
|
295
|
1.30
|
4.7
|
|
0.0841
|
303
|
1.33
|
4.8
|
|
0.0844
|
304
|
1.34
|
4.9
|
|
0.0863
|
311
|
1.37
|
5.0
|
|
Точность: Наибольшее значение: ±5% от контролируемого расхода или ±2% от максимального расхода. |