Технические характеристики регуляторов расхода вохдуха в прямоугольных каналах Systemair Optima-S и Systemair Optima-S-I
Определение кода заказа регуляторов расхода Systemair Optima-S

Габаритные размеры регуляторов расхода воздуха Systemair Optima-S и Systemair Optima-S-I
|
|
|
Systemair Optima-S (масса, кг)
|
|||||||||||||||||||||
|
H \ W
|
200
|
250
|
300
|
350
|
400
|
450
|
500
|
550
|
600
|
650
|
700
|
750
|
800
|
850
|
900
|
950
|
1000
|
1050
|
1100
|
1150
|
1200
|
|
100
|
2
|
2
|
3
|
4
|
4
|
5
|
5
|
6
|
6
|
|
|
|
|
|
|
|
|
|
|
|
|
|
150
|
4
|
5
|
5
|
6
|
6
|
6
|
7
|
7
|
8
|
9
|
|
|
|
|
|
|
|
|
|
|
|
|
200
|
6
|
7
|
7
|
8
|
8
|
8
|
9
|
9
|
10
|
10
|
10
|
11
|
11
|
12
|
12
|
|
|
|
|
|
|
|
250
|
|
7
|
7
|
9
|
9
|
9
|
9
|
9
|
10
|
10
|
11
|
12
|
12
|
13
|
14
|
14
|
|
|
|
|
|
|
300
|
|
|
8
|
9
|
10
|
9
|
9
|
10
|
10
|
11
|
12
|
13
|
14
|
15
|
19
|
19
|
21
|
21
|
22
|
|
|
|
350
|
|
|
9
|
10
|
11
|
10
|
10
|
10
|
11
|
12
|
13
|
14
|
15
|
17
|
19
|
20
|
22
|
22
|
24
|
25
|
|
|
400
|
|
|
|
|
12
|
12
|
11
|
11
|
12
|
13
|
14
|
15
|
17
|
19
|
20
|
23
|
25
|
26
|
27
|
28
|
29
|
|
450
|
|
|
|
|
|
12
|
13
|
13
|
13
|
14
|
16
|
17
|
19
|
21
|
21
|
24
|
26
|
27
|
28
|
29
|
30
|
|
500
|
|
|
|
|
|
|
15
|
14
|
15
|
16
|
18
|
19
|
21
|
22
|
23
|
25
|
28
|
29
|
30
|
31
|
32
|
|
550
|
|
|
|
|
|
|
|
16
|
17
|
18
|
20
|
21
|
22
|
24
|
24
|
26
|
29
|
30
|
31
|
32
|
34
|
|
600
|
|
|
|
|
|
|
|
|
19
|
20
|
21
|
22
|
24
|
25
|
25
|
27
|
30
|
32
|
33
|
34
|
36
|
|
650
|
|
|
|
|
|
|
|
|
|
22
|
23
|
24
|
25
|
27
|
27
|
29
|
32
|
33
|
35
|
36
|
38
|
|
700
|
|
|
|
|
|
|
|
|
|
|
25
|
26
|
27
|
29
|
29
|
31
|
34
|
35
|
37
|
38
|
40
|
|
750
|
|
|
|
|
|
|
|
|
|
|
|
27
|
29
|
30
|
31
|
33
|
36
|
37
|
38
|
40
|
42
|
|
800
|
|
|
|
|
|
|
|
|
|
|
|
|
30
|
31
|
32
|
34
|
37
|
38
|
40
|
42
|
43
|
|
850
|
|
|
|
|
|
|
|
|
|
|
|
|
|
32
|
34
|
35
|
38
|
39
|
41
|
43
|
45
|
|
900
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
35
|
37
|
40
|
41
|
43
|
45
|
47
|
|
950
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
39
|
41
|
43
|
45
|
47
|
49
|
|
1000
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
43
|
45
|
47
|
49
|
50
|
|
Systemair Optima-S-I (масса, кг)
|
|||||||||||||||||||||
|
H \ W
|
200
|
250
|
300
|
350
|
400
|
450
|
500
|
550
|
600
|
650
|
700
|
750
|
800
|
850
|
900
|
950
|
1000
|
1050
|
1100
|
1150
|
1200
|
|
100
|
3
|
3
|
5
|
6
|
6
|
8
|
8
|
9
|
9
|
|
|
|
|
|
|
|
|
|
|
|
|
|
150
|
6
|
8
|
8
|
9
|
9
|
9
|
11
|
11
|
12
|
14
|
|
|
|
|
|
|
|
|
|
|
|
|
200
|
9
|
11
|
11
|
12
|
12
|
12
|
14
|
14
|
15
|
15
|
15
|
17
|
17
|
18
|
18
|
|
|
|
|
|
|
|
250
|
|
11
|
11
|
14
|
14
|
14
|
14
|
14
|
15
|
15
|
17
|
18
|
18
|
20
|
21
|
21
|
|
|
|
|
|
|
300
|
|
|
12
|
14
|
15
|
14
|
14
|
15
|
15
|
17
|
18
|
20
|
21
|
23
|
29
|
29
|
32
|
32
|
33
|
|
|
|
350
|
|
|
14
|
15
|
17
|
15
|
15
|
15
|
17
|
18
|
20
|
21
|
23
|
26
|
29
|
30
|
33
|
33
|
36
|
38
|
|
|
400
|
|
|
|
|
18
|
18
|
17
|
17
|
18
|
20
|
21
|
23
|
26
|
29
|
30
|
35
|
38
|
39
|
41
|
42
|
44
|
|
450
|
|
|
|
|
|
18
|
20
|
20
|
20
|
21
|
24
|
26
|
29
|
32
|
32
|
36
|
39
|
41
|
42
|
44
|
45
|
|
500
|
|
|
|
|
|
|
23
|
21
|
23
|
24
|
27
|
29
|
32
|
33
|
35
|
38
|
42
|
44
|
45
|
47
|
48
|
|
550
|
|
|
|
|
|
|
|
24
|
26
|
27
|
30
|
32
|
33
|
36
|
36
|
39
|
44
|
45
|
47
|
48
|
51
|
|
600
|
|
|
|
|
|
|
|
|
29
|
30
|
32
|
33
|
36
|
38
|
38
|
41
|
45
|
48
|
50
|
51
|
54
|
|
650
|
|
|
|
|
|
|
|
|
|
33
|
35
|
36
|
38
|
41
|
41
|
44
|
48
|
50
|
53
|
54
|
57
|
|
700
|
|
|
|
|
|
|
|
|
|
|
38
|
39
|
41
|
44
|
44
|
47
|
51
|
53
|
56
|
57
|
60
|
|
750
|
|
|
|
|
|
|
|
|
|
|
|
41
|
44
|
45
|
47
|
50
|
54
|
56
|
57
|
60
|
63
|
|
800
|
|
|
|
|
|
|
|
|
|
|
|
|
45
|
47
|
48
|
51
|
56
|
57
|
60
|
63
|
65
|
|
850
|
|
|
|
|
|
|
|
|
|
|
|
|
|
48
|
51
|
53
|
57
|
59
|
62
|
65
|
68
|
|
900
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
53
|
56
|
60
|
62
|
65
|
68
|
71
|
|
950
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
59
|
62
|
65
|
68
|
71
|
74
|
|
1000
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
65
|
68
|
71
|
74
|
75
|
|
масса (кг)
|
привод 5 Нм
|
+
|
OPTIMA-S
|
+
|
OPTIMA-S-GO
|
+
|
OPTIMA-S-I
|
+
|
OPTIMA-S-I-GO
|
|
масса (кг)
|
привод 10 Нм
|
+
|
OPTIMA-S
|
+
|
OPTIMA-S-GO
|
+
|
OPTIMA-S-I
|
+
|
OPTIMA-S-I-GO
|
|
масса (кг)
|
привод 20 Нм
|
+
|
OPTIMA-S
|
х
|
OPTIMA-S-GO
|
+
|
OPTIMA-S-I
|
х
|
OPTIMA-S-I-GO
|